下载此文档

北京市综合教学楼供暖及绿洲小区换热站设计(全套含CAD图纸).zip


文档分类:建筑/环境 | 页数:约35页 举报非法文档有奖
文件列表
北京市综合教学楼供暖及绿洲小区换热站设计.doc [1.37 MB]
北京市综合教学楼供暖及绿洲小区换热站设计.doc [1.37 MB]
一层采暖平面图.dwg [110.75 KB] 查看图纸
一层采暖平面图.dwg [110.75 KB] 查看图纸
九层采暖平面图.dwg [108.53 KB] 查看图纸
九层采暖平面图.dwg [108.53 KB] 查看图纸
低区水力计算.xls [33 KB]
低区水力计算.xls [33 KB]
低区采暖系统图.dwg [70.41 KB] 查看图纸
低区采暖系统图.dwg [70.41 KB] 查看图纸
低区采暖系统图2.dwg [70.91 KB] 查看图纸
低区采暖系统图2.dwg [70.91 KB] 查看图纸
办公楼供暖及换热站设计任务书.doc [19 KB]
办公楼供暖及换热站设计任务书.doc [19 KB]
十层采暖平面图.dwg [99.06 KB] 查看图纸
十层采暖平面图.dwg [99.06 KB] 查看图纸
四层采暖平面图.dwg [107.25 KB] 查看图纸
四层采暖平面图.dwg [107.25 KB] 查看图纸
图纸汇总.dwg [424.91 KB] 查看图纸
图纸汇总.dwg [424.91 KB] 查看图纸
换热站平面布置图.dwg [97.78 KB] 查看图纸
换热站平面布置图.dwg [97.78 KB] 查看图纸
换热站热力流程图.dwg [221.63 KB] 查看图纸
换热站热力流程图.dwg [221.63 KB] 查看图纸
散热器计算.xls [94.50 KB]
散热器计算.xls [94.50 KB]
热负荷1层.xls [2.08 MB]
热负荷1层.xls [2.08 MB]
热负荷2层 -4层.xls [79.50 KB]
热负荷2层 -4层.xls [79.50 KB]
热负荷5层.xls [33.50 KB]
热负荷5层.xls [33.50 KB]
热负荷6层 - 8层.xls [77 KB]
热负荷6层 - 8层.xls [77 KB]
热负荷9层.xls [40 KB]
热负荷9层.xls [40 KB]
设计说明书.doc [1.25 MB]
设计说明书.doc [1.25 MB]
负荷各层.xls [17.50 KB]
负荷各层.xls [17.50 KB]
高区水力计算.xls [31.50 KB]
高区水力计算.xls [31.50 KB]
1/35
下载提示
  • 1.该资料是网友上传的,本站提供全文预览,预览什么样,下载就什么样。
  • 2.下载该文档所得收入归上传者、原创者。
  • 3.下载的文档,不会出现我们的网址水印。
1/35 下载此文档
文档介绍
摘要
本次毕业设计的任务是北京市一栋综合教学楼的供热系统施工设计及绿洲小区换热站施工设计。
,㎡。采暖部分为9层,供热除了楼梯间与大厅的所有房间。
热源采用的是市政热网,室内采暖供回水温度为85/60℃。以北京市当地的冬季室外气象参数及围护结构的热工计算参数为依据,计算出该综合教学楼的热负荷。
根据教学楼结构,房间用途和及经济性和技术可行性比较,采用了竖向分两区,各区又分两支,垂直单管顺流上供下回同程式热水采暖系统。
本次设计采用散热器供暖的采暖方式,考虑到到新型散热器--铜铝散热器较传统铸铁等散热器的优点,选用该种类型的散热器。根据教学楼内各房间负荷大小(预计算需散热器组数)及构造,将系统立管位置确定,算出各组散热器片数,做出水力计算草图并进行水力计算。
最后根据小区整体情况,进行换热站设计。
关键词:热负荷散热器水力计算换热站
ABSTRACT
The graduation project's mission is to Beijing prehensive teaching building design and construction of heating systems heat transfer station construction design district oasis.
Teaching building building height is , gross floor area of approximately 9, square meters. Heating part of the 9-layer, heat in addition to the stairwell and hall all rooms.
Heat is used in municipal work, indoor heating supply and return water temperature of 85/60 ℃. In Beijing the local winter outdoor meteorological parameters and the thermal envelope calculation parameters as the basis to calculate prehensive teaching building heat load.
According to the teaching building structure, purpose and the room and the technical feasibility and parison, using a vertical two-zone, the district was divided into two vertical single-pipe memorial program the next time the same hot water heating system.
The design uses a radiator heating heating methods, taking into account the new radiator - copper and aluminum radiators than traditional cast iron radiators advantages, the choice of this type of radiator. According to the teaching building of the room load size (number of groups puted need radiator) and the structure of the system riser position to determine, calculate the number of each group radiator, make sketches and hydraulic calculation for hydraulic calculations.
Finally, according to the whole cell, conducting heat transfer station design.
Keywords: Heat load radiator hydraulic calculation heat transfer station