目录
·························································1
·························································1
·························································1
·························································3
···················································3
、质量管理点和控制措施···································13
、文明施工与环保措施·····································16
·························································17
、脚手架类倒塌事故应急处理与救援预案······························17
地下设备用房模板工程施工方案
《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2001
《建筑地基基础工程施工质量验收规范》GB50202—2002
《建筑工程施工质量验收统一标准》GB20300—2001
《建筑施工安全检查标准》JGJ59—99
《建筑施工模板安全技术规范》JGJ162—2008
本工程为天津八里台工业园区服务中心地下设备用房项目,位于津南区八里台镇工业园区内;设备间为地下一层,地上一层,,东区西区各一个,,,地上:;建筑结构形式为框架结构,抗震设防烈度为7度设计使用年限50年,建筑耐火等级地上地下均为一级
:地下室外墙350厚,内墙厚度为300厚
(mm):
设备房(方形柱):500×500
(mm):
设备房框架梁:350*650、400*900、300*500
设备房次梁:250*600
(mm):
设备房底板:600mm
(mm):
地下室顶板:160mm
:
梁板式楼梯
地下设备用房施工分为二个施工段,各施工段竖向划分为底板以下(外墙上返300高)和底板以上二个施工段。
根据施工进度计划,各施工段施工部位工期安排见下表1:
施工部位
施工时间
工期(天)
底板施工
设备房施工
东区
—
15
西区
—
15
东区
—
30
西区
—
30
表1 施工部位及工期安排表
1、项目技术负责人
全面负责项目技术、质量工作
2、专项技术员
1)对模板工程进行技术交底。
2)对施工过程进行监控
3)负责模板工程技术监控
3、专项质量员
1)对模板工程进行质量监控,检查、督促质量的整改
2)对建材质量进行检查、监控
根据施工进度计划及施工流水段划分进行劳动力安排,主要劳动力分工及数量(见表2)。
序号
工种
部位
人数
底板
设备房结构
1
木工
基础工程
20
40
2
电焊工
3
5
3
架子工
10
60
项目总工组织项目部技术、生产人员熟悉图纸,认真学****掌握施工图的内容、要求和特点,同时针对有关施工技术和图纸存在的问题做好记录,通过会审对图纸中存在的问题,与设计、甲方、监理共同协商解决,取得一致同意后,办理图纸会审记录,作为施工图的变更依据和施工操作依据,熟悉各部位截面尺寸标高,制定初步设计方案。
表3:主要机具及工具准备
名称
规格
功率
数量
锤子
重量:、
/
50个
单头扳手
开口宽(mm):17-19,22-24
/
50个
圆盘锯