摘要
本设计为办公楼空调设计,该空调系统为舒适性空调系统。该办公楼集中会议、办公,休闲于一体。地下一层,地上十二层,建筑总面积16200m2,。
该空调系统为舒适性空调系统。本设计主要是针对办公室﹑活动室及餐厅等功能进行空调设计。为办公人员、来访人员等提供一个舒适健康的环境。本设计根据该建筑各部分的结构特点及其用途,在充分考虑室内环境的舒适性、运行管理上的
方便和节能等各方面的基础上,对一楼北面展厅大空间采用了全空气系统,而对办公室等小空间采用风机盘管加新风系统。这样可以满足不同功能房间使用时间段人员活动情况的不同要求,布置灵活,控制方便。
该建筑外围护结构采用了保温墙体和保温窗体,在节能上起了一定的效果。冷热源采用的是活塞式制冷机组和燃油热水锅炉。根据计算所得的总冷负荷和水的总流量,选择了3台活塞式冷水机组,根据总的热负荷和水的总流量,选择一台燃油热水锅炉。并根据建筑特点采用了相应的防排烟措施。
关键词:节能风机盘管加新风系统全空气系统防排烟控制
Abstract
The HV&AC design for the Shanghai fenghuang office building,belongs fortable air conditioning. .It mainly includes office , refectory and some other different rooms which have different functions .Ground floor level, ground floor, 12, the total construction area of 16200 m2, the top of the building height of m. air-conditioned area of 12000 m2..
The air-conditioning systems for fort of air-conditioning systems. This design is targeted mainly office ﹑ activity rooms and restaurants, and other functions carried out air-conditioning design. For the office staff, visitors and other staff provide fortable and healthy environment. According to the architectural design of the different parts of the structural features and its use, taking full account of the indoor environment fort, convenience on the operation and management and energy conservation, and other areas on the basis of the first floor of the north hall of a large space of the entire air system, And the use of office space and other small fan-coil and a new air system. This room used to meet the different functions of the staff time to the activities of the different requirements, layout flexibility and convenient control.
The building structure used for the external wall insulation and window insulation, energy-saving play in a certain effect. Cold and heat source is used in refrigeration units and piston-type hot water boiler fuel. According to the construction and use of the corresponding characteristics of smoke control measures.
Keywords: