-2- The Engineering Society Land Sea Air and Space 帀 INTERNATIONAL SAE Tech nical Stan dards Board Rules providemove the cans. The first pan elist should positi on his head n ear the con trol can (about 15 cm away) and remove the lid. Then, with a cupped hand, he should draw the air from the can to his nose and slowly in hale. He should the n immediately repeat the procedure for the first test specime n (dry) and record the appropriate rati ng listed in Secti on 6. Lids should not be off the cans lon ger tha n 5 s. Tests must be con ducted in an en viro nment free from drafts and con tam inant odors. Wait 2 min and repeat step for the wet test specime ns. Repeat steps and for each sample. Replace the cans in the ove n for 15 min betwee n observers and repeat steps , , and for at least three pan elists. Report descripti on of test samples, media n and range of rat in gs, and any deviati ons from the test procedure. Odor Scale — See Table 1. TABLE 1 — ODOR SCALE Rating Description 1 No noticeable odor 2 Slight, but noticeable odor 3 Definite odor, but not strong enough to be offensive 4 Strong offensive odor 5 Very strong offensive odor Note that the scale is arbitrary. Since the test applies to a variety of materials and applicati on s, it is not practical to assig n a sta ndard for each rati ng. The tester has the resp on sibi