WCDMA基站测试规范 1 测试规范 3GPP TS 发射测试 接收测试 性能测试 测试模式 总共有5个测试模式(test mode1-test mode5)用于发射测试 接收测试使用RMC 同终端测试不同,BTS测试还需要对多载波进行测试 WCDMA基站测试 2 工作波段和频率 WCDMA基站测试 Operating Band UL Frequencies UE transmit, Node B receive DL frequencies UE receive, Node B transmit I 1920 – 1980 MHz 2110 – 2170 MHz II 1850 –1910 MHz 1930 – 1990 MHz III 1710 -1785 MHz 1805 - 1880 MHz IV 1710 -1755MHz 2110 - 2155MHz V 824 - 849MHz 869 - 894MHz VI 830 - 840 MHz 875 - 885 MHz VII 2500 - 2570 MHz 2620 - 2690 MHz VIII 880 – 915 MHz 925 – 960 MHz IX - MHz - MHz X 1710 – 1770 MHz 2110 – 2170 MHz 信道号= 5 * (FDL – FDL_Offset), FDL_low <= FDL<= FDL_high 3 Base Station Maximum Output Power MS2690A 1. BTS transmits Test Model 1 at Pmax. 2. Measure the mean power by MS8609A. Specification: Test Model 1 (Pmax) ATT BTS Tx B0472 High Power ATT clock 4 CPICH Power Accuracy 1. BTS transmits Test Model 2 at Pmax. *Inner loop power control is OFF. 2. Measure P-CPICH code domain power by MS8609A. Specification: Test Model 2 (Pmax) ATT BTS Tx B0472 High Power ATT clock MS2690A 5 Frequency Error 1. BTS transmits Test Model 1 at Pmax. 2. Measure “Frequency Error” and “Error Vector Magnitude” by MS8609A. 3. BTS transmits Test Model 4 at Pmax-18dB. 4. Measure “Frequency Error” and “Error Vector Magnitude” by MS8609A. Specification: (– PPM – 12 Hz) to (+ PPM + 12 Hz) Test Model 1 (Pmax) Test Model 4 (Pmax-18dB) ATT BTS Tx B0472 High Power ATT clock MS2690A 6 Power Control Dynamic Range 1. BTS transmits Test Model 1 at Pmax and measure. And then changes Test Model 2. 2. set the code domain power of the DPCH under test to Pmax-3 dB and set other code channels to the adequate levels. 3. Measure average power of test code channel. 4. Set the code domain power of the DPCH under test to Pmax-28 dB by means determined by the manufacturer. The power levels for the other