大容量锅炉高温受热面超温失效原因及对策
作者:佚名文章来源:不详点击数:
299 更新时间:
2008-9-24 8:44:20
摘要:近年来,大容量锅炉高温受热面超温爆管现象普遍,严重危及了机组的安全、经
济运行。为此,结合超温爆管事故,分析了高温受热面超温原因,介绍了受热面管子因过热或高温腐蚀而失效的机理,并提出了解决问题的相应技术措施。
关键词:大容量锅炉;受热面;超温;爆管;失效;对策
Overtemperature failures of hightemperature heating surface in large
capacityboilers: cause analysis and countermeasures
CHENG Shaobing1, TAN Changyou2
(1. Guangdong Electric Power Industrial School, Guangzhou 510520, China;
2. Guan gdong GuangDian Power Grid Group Co., Ltd., Guangzhou 510600, China)
Abstract: The prevalent overtemperature caused tube bursting of high tempera tu re heating surface in largecapacity boilers in recent years has seriously enda n gered the safe and economic operation of units. This paper
analyzes the causes of the overtemperature problem,describes the mechanism of heating surfa ce tube failures due to overheat or hightemperature corrosion, and pu ts forward some countermeasures. Keywords: largecapacity boiler;
heating surface;
overtemperature;
tubebursting;
failure;
countermeasure
现代大型火力发电厂锅炉过热蒸汽器、再热蒸汽器超温爆管现象较普遍,不论是国产型、引进型、进口型都发生过超温爆管事故,严重影响机组的安全运行。现以200 MW, 300 MW机组锅炉过热蒸汽器、再热蒸汽器为例,对其超温失效原因进行分析,并提出相应的防止措施,供电厂锅炉工作者参考、借鉴。 1受热面超温原因分析
四角布置切圆燃烧方式的锅炉,在炉膛出口处存在着一定的残余气流旋转,使沿炉膛宽度方向的炉膛出口烟温和烟速分布存在一定偏差。燃烧器的布置方式,如各股气流的引入角度,一、二、三次风的动量比,气流切圆直径影响到气流的旋转强度,进而影响水平烟道的烟温分布,这些因素都使实际的受热面吸热产生了偏差。因此,烟气温度场和速度场的分布偏差是
大容量锅炉高温受热面超温失效原因及对策 来自淘豆网www.taodocs.com转载请标明出处.